{"product_id":"schneider-tsxsay100-as-i-master-module-31-slaves-standard-addressing","title":"Schneider TSXSAY100 AS-i Master Module 31 Slaves Standard Addressing","description":"\u003ch2\u003eSchneider Electric TSXSAY100 - AS-Interface Master Module, Modicon Premium, 31 Slaves, Standard Addressing\u003c\/h2\u003e\n\n\u003cp class=\"meta\"\u003eBrand: \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e  |  Range of product: \u003cstrong\u003eModicon Premium automation platform\u003c\/strong\u003e  |  Product or component type: \u003cstrong\u003eAS-Interface master module\u003c\/strong\u003e  |  AS-i master profile: \u003cstrong\u003eM2\u003c\/strong\u003e  |  Number of slaves: \u003cstrong\u003e31, standard addressing\u003c\/strong\u003e  |  Electrical connection: \u003cstrong\u003e1 male connector SUB-D, 3 ways\u003c\/strong\u003e  |  Current consumption: \u003cstrong\u003e110 mA typical \/ 150 mA max at 5 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TSXSAY100 is an AS-Interface (AS-i) master module of the Schneider Electric Modicon Premium automation platform. It manages one AS-i bus segment as channel 0 of the module, with up to 31 slaves using standard addressing. The AS-i master profile is M2, the maximum cycle time on the AS-i bus is 5 ms and the maximum bus length is 100 meters including all branches, without a repeater.\u003c\/p\u003e\n\n\u003cp\u003eThe module supports a maximum of 124 inputs and 124 outputs on the AS-i bus. Standard addressing gives each slave 4 inputs and 4 outputs, and the 32-LED display panel at the front of the module reports the slaves present on the bus and their input\/output states. Local signalling is by a display unit with RUN, ERR, COM and I\/O LEDs for the module, plus AS-i, BUS and I\/O LEDs for the bus; the panel works in bus display mode or in slave display mode (SLV), selected with the push buttons on the module. Automatic addressing of slaves can be enabled in the module configuration, so a faulty slave can be replaced by a slave of the same type and profile without stopping the AS-i bus.\u003c\/p\u003e\n\n\u003cp\u003eThe electrical connection is 1 male SUB-D connector, 3 ways, for the AS-i bus. The module is powered from the host platform: it takes 5 V DC from the rack backplane, with a current consumption of 110 mA typical and 150 mA maximum, and its electrical 0 V is connected to the PLC ground. On the AS-i side the nominal bus supply voltage is 30 V DC from an AS-i power supply, with a current of 50 mA typical and 60 mA maximum; the AS-i power supply must be a SELV supply, and protection against polarity inversion is provided on the AS-i bus inputs.\u003c\/p\u003e\n\n\u003cp\u003eThe module is programmed with PL7 Junior \/ PL7 Pro or Unity Pro software. With 31 slaves and a PLC scan time of 10 ms, the response time is typically 27 ms and 37 ms maximum. Operating temperature is 0...60 °C without ventilation and storage temperature is -25...70 °C, with a degree of protection of IP20. The module conforms to IEC 60068-2-27 (Ea tests) and IEC 60068-2-6 (Fc tests). Net weight is 0.3 kg; packing unit 1 is 1 piece, 26.4 cm long, 18 cm wide and 5.5 cm high, with a packing weight of 452 g.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon Premium automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eAS-Interface master module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange compatibility\u003c\/td\u003e\n\u003ctd\u003eAS-Interface cabling system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i master profile\u003c\/td\u003e\n\u003ctd\u003eM2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing\u003c\/td\u003e\n\u003ctd\u003eStandard addressing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of slaves\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum cycle time on AS-i bus\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum length of AS-i bus\u003c\/td\u003e\n\u003ctd\u003e100 m, all branches included, without repeater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum number of I\/O\u003c\/td\u003e\n\u003ctd\u003e124 inputs + 124 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAS-i bus nominal supply voltage\u003c\/td\u003e\n\u003ctd\u003e30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003e1 male connector SUB-D, 3 ways\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply\u003c\/td\u003e\n\u003ctd\u003eVia power supply integrated into the host platform of the module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption at 5 V DC\u003c\/td\u003e\n\u003ctd\u003e110 mA typical; 150 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption on AS-i 30 V\u003c\/td\u003e\n\u003ctd\u003e50 mA typical; 60 mA maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection against polarity inversion\u003c\/td\u003e\n\u003ctd\u003eOn AS-i bus inputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003eDisplay unit: RUN, ERR, COM, I\/O LEDs; AS-i, BUS, I\/O LEDs; 32-LED panel in bus or slave (SLV) display mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgramming\u003c\/td\u003e\n\u003ctd\u003ePL7 Junior \/ PL7 Pro; Unity Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time with 31 slaves, 10 ms PLC scan time\u003c\/td\u003e\n\u003ctd\u003eTypically 27 ms; 37 ms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic addressing of slaves\u003c\/td\u003e\n\u003ctd\u003eConfigurable, allows replacement of a faulty slave with a slave of the same type and profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C, without ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e-25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 60068-2-27 (Ea tests); IEC 60068-2-6 (Fc tests)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 type\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 length\u003c\/td\u003e\n\u003ctd\u003e26.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 width\u003c\/td\u003e\n\u003ctd\u003e18.0 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 height\u003c\/td\u003e\n\u003ctd\u003e5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking weight\u003c\/td\u003e\n\u003ctd\u003e452 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68314385809496,"sku":null,"price":1208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/TSXSAY100......jpg?v=1795507504","url":"https:\/\/gexufein.com\/products\/schneider-tsxsay100-as-i-master-module-31-slaves-standard-addressing","provider":"Gexufein Automation","version":"1.0","type":"link"}