{"product_id":"schneider-tsxdsy16t2-discrete-output-module-16-channel-24v-dc","title":"Schneider TSXDSY16T2 Discrete Output Module 16 Channel 24V DC","description":"\u003ch2\u003eTSXDSY16T2 - Discrete Output Module, 16 Solid State Outputs, 24 V DC, 0.5 A\u003c\/h2\u003e\n\n\u003cp\u003eProduct type: \u003cstrong\u003eDiscrete Output Module\u003c\/strong\u003e  |  Range: \u003cstrong\u003eModicon Premium\u003c\/strong\u003e  |  Outputs: \u003cstrong\u003e16 solid state, positive logic\u003c\/strong\u003e  |  Output current: \u003cstrong\u003e0.5 A per channel\u003c\/strong\u003e  |  Connection: \u003cstrong\u003escrew terminal block\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TSXDSY16T2 is a 16-channel discrete output module of the Modicon Premium automation platform. It is a standard format module and occupies one slot in the rack. All 16 outputs are solid state (transistor) outputs with positive logic, so the module sources current to the load. It is built to drive 24 V DC loads directly: relay coils, solenoid valves, indicator lamps and small DC contactors. Because the outputs are solid state and not relay contacts, the module switches DC loads only and cannot be used on an AC circuit.\u003c\/p\u003e\n\n\u003cp\u003eThe output voltage is 24 V DC positive, conforming to EN\/IEC 61131-2 over a range of 19 to 30 V. Rated output current is 0.5 A, the maximum current per channel is 0.625 A, and the maximum current per module is 7 A. Response time is 1.2 ms and the switching frequency is 0.5\/LI² Hz. At state 0 the maximum leakage current is 0.5 mA and the residual voltage is 1.2 V. The preactuator voltage detection threshold is 16 V and the minimum load impedance is 48 Ohm, which corresponds to 24 V at 0.5 A.\u003c\/p\u003e\n\n\u003cp\u003eEach output is protected on the module itself, which is the main difference from the relay version TSXDSY16R5. Overvoltage on the output is clamped by a transil diode, reverse polarity is handled by a reverse mounted diode, and overload and short circuit are cleared by electronic tripping on reactivation, with no external fuse required. Inductive DC loads should still be fitted with a freewheeling diode across the coil to limit the energy the transil has to absorb.\u003c\/p\u003e\n\n\u003cp\u003eField wiring uses a 16-channel screw terminal block. The module takes its logic supply from the rack and draws 80 mA at 5 V DC; the load side needs a separate 24 V DC supply. Power dissipation is calculated as 1.1 W plus 0.75 W multiplied by the number of outputs in state 1 and the current per module. Insulation resistance is above 10 MOhm at 500 V and dielectric strength is 1500 V at 50\/60 Hz for 60 seconds.\u003c\/p\u003e\n\n\u003cp\u003eOperating temperature is 0 to 60 °C and storage temperature −25 to 70 °C. Relative humidity is 10 to 95 % without condensation in operation and 5 to 95 % in storage, operating altitude is up to 2000 m, protection degree is IP20, pollution degree is 2 and the protective treatment is TC. The module is marked CE and conforms to 73\/23\/EEC, 92\/31\/EEC, 89\/336\/EEC and IEC 61131-2, with UL 508, CSA C22.2 No 142 and CSA C22.2 No 213 Class I Division 2 groups A, B, C and D. Marine certifications are BV, RINA, LR, ABS, RMRS, GL and DNV. Net weight is 0.34 kg; one piece is packed in a 26 x 18 x 5.5 cm carton of 453 g.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon Premium automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eDiscrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eSolid state protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput logic\u003c\/td\u003e\n\u003ctd\u003ePositive (sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC positive (EN\/IEC 61131-2: 19...30 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per channel\u003c\/td\u003e\n\u003ctd\u003e0.625 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum current per module\u003c\/td\u003e\n\u003ctd\u003e7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e1.2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSwitching frequency\u003c\/td\u003e\n\u003ctd\u003e0.5\/LI² Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum leakage current\u003c\/td\u003e\n\u003ctd\u003e0.5 mA at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual voltage [Ures]\u003c\/td\u003e\n\u003ctd\u003e1.2 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreactuator voltage detection threshold\u003c\/td\u003e\n\u003ctd\u003e16 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum load impedance\u003c\/td\u003e\n\u003ctd\u003e48 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput overvoltage protection\u003c\/td\u003e\n\u003ctd\u003eBy transil diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse polarity protection\u003c\/td\u003e\n\u003ctd\u003eReverse mounted diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput overload protection\u003c\/td\u003e\n\u003ctd\u003eElectronic tripping on reactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003eElectronic tripping on reactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric strength\u003c\/td\u003e\n\u003ctd\u003e1500 V, 50\/60 Hz, 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block, 16 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at 5 V DC (rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation\u003c\/td\u003e\n\u003ctd\u003e1.1 W + 0.75 W x number of outputs x current per module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e−25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10...95 % without condensation (operation); 5...95 % without condensation (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e73\/23\/EEC, 92\/31\/EEC, 89\/336\/EEC, IEC 61131-2, UL 508, CSA C22.2 No 142, CSA C22.2 No 213 Class I Division 2 groups A\/B\/C\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eBV, RINA, LR, ABS, RMRS, GL, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit weight\u003c\/td\u003e\n\u003ctd\u003e453 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit dimensions\u003c\/td\u003e\n\u003ctd\u003e26 x 18 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68241726963800,"sku":null,"price":56.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/TSXDSY16T2......jpg?v=1794891724","url":"https:\/\/gexufein.com\/products\/schneider-tsxdsy16t2-discrete-output-module-16-channel-24v-dc","provider":"Gexufein Automation","version":"1.0","type":"link"}