{"product_id":"schneider-tsxdsy16r5-discrete-output-module-16-relay-output","title":"Schneider TSXDSY16R5 Discrete Output Module 16 Relay Output","description":"\u003ch2\u003eTSXDSY16R5 - Discrete Output Module, 16 Relay Outputs, 24 V DC \/ 240 V AC\u003c\/h2\u003e\n\n\u003cp\u003eProduct type: \u003cstrong\u003eDiscrete Output Module\u003c\/strong\u003e  |  Range: \u003cstrong\u003eModicon Premium\u003c\/strong\u003e  |  Outputs: \u003cstrong\u003e16 relay, 1 NO\u003c\/strong\u003e  |  Thermal current: \u003cstrong\u003e3 A\u003c\/strong\u003e  |  Connection: \u003cstrong\u003eremovable screw terminal block\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe TSXDSY16R5 is a 16-channel relay output module of the Modicon Premium automation platform. It is a standard format module and takes one slot in the rack. Each of the 16 outputs is a normally open (1 NO) electromechanical relay contact, which can switch a DC or an AC load directly, so contactors, solenoid valves, indicator lamps and small resistive or inductive loads can be driven without an interposing relay. Because the contacts are dry relay contacts, mixed DC and AC voltages are possible in the same module.\u003c\/p\u003e\n\n\u003cp\u003eThe output voltage is 12 to 24 V DC (10 to 34 V to EN\/IEC 61131-2) and 24 to 240 V AC (20 to 264 V to EN\/IEC 61131-2). The conventional free air thermal current is 3 A. Response time is below 8 ms on activation and below 10 ms on deactivation. Electrical durability is rated at 1 000 000 cycles for DC-12 24 V 24 W resistive and DC-3 24 V 24 W inductive loads, 1 000 000 cycles for AC-12 220 VA 220 V resistive loads, and 3 000 000 cycles for AC-14 \/ AC-15 50 VA 220 V inductive loads.\u003c\/p\u003e\n\n\u003cp\u003eThe output type is a relay that is not protected, which is the point to check before wiring: there is no built-in overcurrent or short-circuit protection on the contacts. One external fast-blow fuse per channel or per group of channels is required for overload and short-circuit protection. Overvoltage on inductive loads is handled on each preactuator, by a discharge diode for DC inductive loads and by an RC circuit with MOV (ZNO) for AC inductive loads. Insulation resistance is above 10 MOhm at 500 V and dielectric strength is 2000 V at 50\/60 Hz for 60 seconds.\u003c\/p\u003e\n\n\u003cp\u003eField wiring uses a removable 16-post screw terminal block, which carries a device that transfers the terminal coding automatically the first time it is used, so a module can be replaced without mixing up the wires. The module draws 80 mA at 5 V DC and 135 mA at 24 V DC from the rack. Power dissipation is 0.25 W plus 0.2 W per output in state 1, which is where the 0.25 W in the product name comes from.\u003c\/p\u003e\n\n\u003cp\u003eOperating temperature is 0 to 60 °C and storage temperature −25 to 70 °C. Relative humidity is 10 to 95 % without condensation in operation and 5 to 95 % in storage, operating altitude is up to 2000 m, protection degree is IP20 and the protective treatment is TC. The module is marked CE and conforms to 73\/23\/EEC, 92\/31\/EEC, 89\/336\/EEC, 93\/68\/EEC and IEC 61131-2, with UL 508, CSA C22.2 No 142 and CSA C22.2 No 213 Class I Division 2 groups A, B, C and D. Marine certifications are BV, RINA, LR, ABS, RMRS, GL and DNV. Net weight is 0.38 kg; one piece is packed in a 26 x 18 x 5.5 cm carton of 482 g, and the contractual warranty is 18 months.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon Premium automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eDiscrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output number\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output type\u003c\/td\u003e\n\u003ctd\u003eRelay, not protected\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContacts type and composition\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output voltage\u003c\/td\u003e\n\u003ctd\u003e12...24 V DC (EN\/IEC 61131-2: 10...34 V); 24...240 V AC (EN\/IEC 61131-2: 20...264 V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConventional free air thermal current [Ith]\u003c\/td\u003e\n\u003ctd\u003e3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 8 ms activation, \u0026lt; 10 ms deactivation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput overload protection\u003c\/td\u003e\n\u003ctd\u003e1 external fast-blow fuse per channel or group of channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-circuit protection\u003c\/td\u003e\n\u003ctd\u003e1 external fast-blow fuse per channel or group of channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput overvoltage protection\u003c\/td\u003e\n\u003ctd\u003eDC inductive: discharge diode on each preactuator; AC inductive: RC circuit with MOV (ZNO) on each preactuator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical durability\u003c\/td\u003e\n\u003ctd\u003e1 000 000 cycles DC-12 24 V 24 W resistive; 1 000 000 cycles DC-3 24 V 24 W inductive; 1 000 000 cycles AC-12 220 VA 220 V resistive; 3 000 000 cycles AC-14 \/ AC-15 50 VA 220 V inductive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric strength\u003c\/td\u003e\n\u003ctd\u003e2000 V, 50\/60 Hz, 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical connection\u003c\/td\u003e\n\u003ctd\u003eRemovable 16-post screw terminal block, automatic terminal coding transfer on first use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e80 mA at 5 V DC; 135 mA at 24 V DC (rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation\u003c\/td\u003e\n\u003ctd\u003e0.25 W + 0.2 W x number of outputs in state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtective treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e−25...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e10...95 % without condensation (operation); 5...95 % without condensation (storage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003e73\/23\/EEC, 92\/31\/EEC, 89\/336\/EEC, 93\/68\/EEC, IEC 61131-2, UL 508, CSA C22.2 No 142, CSA C22.2 No 213 Class I Division 2 groups A\/B\/C\/D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eBV, RINA, LR, ABS, RMRS, GL, DNV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCountry of origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit weight\u003c\/td\u003e\n\u003ctd\u003e482 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit dimensions\u003c\/td\u003e\n\u003ctd\u003e26 x 18 x 5.5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e18 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68199390085208,"sku":null,"price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/TSXDSY16R5.....jpg?v=1794562448","url":"https:\/\/gexufein.com\/products\/schneider-tsxdsy16r5-discrete-output-module-16-relay-output","provider":"Gexufein Automation","version":"1.0","type":"link"}