{"product_id":"schneider-stbddi3615k-basic-digital-input-kit-6-di-24v-dc","title":"Schneider STBDDI3615K Basic Digital Input Kit 6 DI 24V DC","description":"\u003ch2\u003eSTBDDI3615K - Modicon STB Basic Digital Input Kit, 6 DI, 24 V DC\u003c\/h2\u003e\n\n\u003cp\u003eProduct type: \u003cstrong\u003eBasic Digital Input Kit\u003c\/strong\u003e  |  Range: \u003cstrong\u003eModicon STB\u003c\/strong\u003e  |  Inputs: \u003cstrong\u003e6 DI, 24 V DC\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe STBDDI3615K is a basic digital input kit from the Modicon STB distributed I\/O range. It is supplied as a complete assembly: the STBDDI3615 input module, the STBXBA1000 I\/O base, and two alternative 6-terminal connectors, STBXTS1100 screw type and STBXTS2100 spring clamp. The module provides six discrete inputs at 24 V DC with positive logic and is intended for sensors and switches wired at the machine, on an STB island segment. The bare module STBDDI3615 does not include the base or the connectors; the K version does.\u003c\/p\u003e\n\n\u003cp\u003eEach channel reads 15 to 30 V DC as state 1 and −3 to 5 V DC as state 0, drawing 4.5 mA. Permissible voltage is 30 V, with an absolute maximum of 56 V for 1.3 ms. Response time is 5.25 ms off-to-on and 5.75 ms on-to-off, with 5 ms input filtering to reject contact bounce and noise from adjacent drives. Insulation between the channels and the logic bus is 1500 V for 1 minute. Inputs are protected against reverse polarity and current limited by resistor; the power distribution module carries an integrated 5 A time-lag fuse.\u003c\/p\u003e\n\n\u003cp\u003eThe module is 18.4 mm wide on the rail, 125 mm high and 65.1 mm deep. It clips onto the STBXBA1000 base, and the assembled unit mounts on 35 x 7.5 mm or 35 x 15 mm symmetrical DIN rail. Cold swapping is supported, and hot swapping is supported when the island runs with a basic NIM. A green RDY LED shows module status and one green LED per channel, IN1 to IN6, shows the field state, so commissioning can be done without a programming terminal. Protection is IP20 to EN 61131-2 class 1, overvoltage category II and pollution degree 2.\u003c\/p\u003e\n\n\u003cp\u003eField power is distributed by the STBPDT3100 or STBPDT3105 power distribution module, which feeds 24 V DC to the sensors. The module itself draws 45 mA at 5 V DC from the logic bus, so the island current budget has to be checked against the NIM and the PDM before a segment is extended. Six terminals are used per connector, one per channel.\u003c\/p\u003e\n\n\u003cp\u003eOperating temperature is 0 to 60 °C without derating, storage −40 to 85 °C, relative humidity 95 % at 60 °C without condensation, and operating altitude up to 2000 m. Vibration resistance is ±0.35 mm from 10 to 58 Hz and 3 gn from 58 to 150 Hz on 35 x 7.5 mm rail, or 5 gn on 35 x 15 mm rail; shock resistance is 30 gn for 11 ms. The module meets EN\/IEC 61131-2 type 1 and carries CE marking, UL and CSA approval, and FM Class 1 Division 2 for hazardous locations.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon STB distributed I\/O solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eBasic digital input kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKit composition\u003c\/td\u003e\n\u003ctd\u003eSTBDDI3615 module, STBXBA1000 base, STBXTS1100 screw connector, STBXTS2100 spring clamp connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input number\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput voltage limits\u003c\/td\u003e\n\u003ctd\u003e15...30 V at state 1, −3...5 V at state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePermissible voltage\u003c\/td\u003e\n\u003ctd\u003e30 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute maximum voltage\u003c\/td\u003e\n\u003ctd\u003e56 V for 1.3 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input current\u003c\/td\u003e\n\u003ctd\u003e4.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete input logic\u003c\/td\u003e\n\u003ctd\u003ePositive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e5.25 ms off-to-on, 5.75 ms on-to-off\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput filtering\u003c\/td\u003e\n\u003ctd\u003e5 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation between channels and logic bus\u003c\/td\u003e\n\u003ctd\u003e1500 V for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eReverse polarity protection, resistor-limited input protection, 5 A time-lag fuse on PDM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold swapping\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHot swapping\u003c\/td\u003e\n\u003ctd\u003eYes for basic NIMs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus LED\u003c\/td\u003e\n\u003ctd\u003e1 green RDY module status, 1 green per channel (IN1 to IN6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent consumption\u003c\/td\u003e\n\u003ctd\u003e45 mA at 5 V DC on logic bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct compatibility\u003c\/td\u003e\n\u003ctd\u003eI\/O base STBXBA1000, PDM STBPDT3100 \/ STBPDT3105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting support\u003c\/td\u003e\n\u003ctd\u003e35 x 7.5 mm and 35 x 15 mm symmetrical DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003e18.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e65.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.112 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP degree of protection\u003c\/td\u003e\n\u003ctd\u003eIP20 to EN 61131-2 class 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePollution degree\u003c\/td\u003e\n\u003ctd\u003e2 conforming to IEC 60664-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C without derating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e−40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95 % at 60 °C without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003eUp to 2000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration resistance\u003c\/td\u003e\n\u003ctd\u003e±0.35 mm 10...58 Hz, 3 gn 58...150 Hz on 35 x 7.5 rail, 5 gn on 35 x 15 rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock resistance\u003c\/td\u003e\n\u003ctd\u003e30 gn for 11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eEN\/IEC 61131-2 type 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eCE, UL, CSA, FM Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68183986274392,"sku":null,"price":112.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/STBDDI3615K...jpg?v=1794482664","url":"https:\/\/gexufein.com\/products\/schneider-stbddi3615k-basic-digital-input-kit-6-di-24v-dc","provider":"Gexufein Automation","version":"1.0","type":"link"}