{"product_id":"schneider-140ddo84300-modicon-quantum-discrete-output-module-16-outputs-10-60v-dc-positive-logic","title":"Schneider 140DDO84300 Modicon Quantum Discrete Output Module 16 Outputs 10-60V DC Positive Logic","description":"\u003ch2\u003eSchneider Electric 140DDO84300 - Discrete Output Module, Modicon Quantum, 16 Outputs 10...60 V DC, Positive Logic\u003c\/h2\u003e\n\n\u003cp class=\"meta\"\u003eBrand: \u003cstrong\u003eSchneider Electric\u003c\/strong\u003e  |  Range of product: \u003cstrong\u003eModicon Quantum automation platform\u003c\/strong\u003e  |  Product or component type: \u003cstrong\u003eDC discrete output module\u003c\/strong\u003e  |  Number of discrete outputs: \u003cstrong\u003e16\u003c\/strong\u003e  |  Channel configuration: \u003cstrong\u003e2 groups of 8\u003c\/strong\u003e  |  Discrete output voltage: \u003cstrong\u003e10...60 V DC\u003c\/strong\u003e  |  Discrete output logic: \u003cstrong\u003ePositive (source)\u003c\/strong\u003e  |  Module class: \u003cstrong\u003eStandard\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 140DDO84300 is a DC discrete output module of the Schneider Electric Modicon Quantum automation platform. It has 16 discrete outputs in 2 groups of 8, with positive (source) output logic and a discrete output voltage of 10...60 V DC. Addressing requires 1 output word, and the module class is standard.\u003c\/p\u003e\n\n\u003cp\u003eOutput voltage limits are 10.2...72 V, and the absolute maximum output is a constant 72 V. Maximum voltage drop is less than 1 V at 2 A. Maximum load current is 12 A per module and 6 A per group, with a surge current of 7.5 A for 50 s. Response time is less than or equal to 1 ms from state 0 to state 1 and less than or equal to 1 ms from state 1 to state 0. Maximum leakage current is 1 mA at 60 V. Load inductance is given by inductance (H) = 0.5 \/ ((current (A))² x (switching frequency (Hz))).\u003c\/p\u003e\n\n\u003cp\u003eProtection is by an internal output protection fuse of 8 A per group. Fuses used with relays are 2 A per point and 8 A per group. Insulation between each channel and the bus is 2500 Vrms DC for 1 minute, and insulation between groups is 700 Vrms DC for 1 minute. Marking is CE.\u003c\/p\u003e\n\n\u003cp\u003ePower consumption is 1 W + (1 V x total module load current). Bus current requirement is 160 mA. Local signalling is 1 green LED for communication on the bus in progress (Active), 1 red LED for detected external fault (F), and 16 green LEDs for the output states.\u003c\/p\u003e\n\n\u003cp\u003eElectrostatic discharge immunity is 4 kV on contact and 8 kV in air according to IEC 801-2, and immunity to electromagnetic fields is 10 V\/m from 80 to 2000 MHz according to IEC 801-3. Operating temperature is 0...60 °C and storage temperature is -40...85 °C, with relative humidity of 95 % without condensation and operating altitude up to 5000 m. The module conforms to CSA C22.2 No 142 and UL 508, and product certifications are GOST, RMRS, FM Class I Division 2 and C-Tick.\u003c\/p\u003e\n\n\u003cp\u003eNet weight is 0.45 kg. Packing unit 1 is 1 piece, 30.91 cm long, 16.33 cm wide and 4.73 cm high, with a packing weight of 452.6 g. Warranty is 18 months.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum automation platform\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eDC discrete output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of discrete outputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel configuration\u003c\/td\u003e\n\u003ctd\u003e2 groups of 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output logic\u003c\/td\u003e\n\u003ctd\u003ePositive (source)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete output voltage\u003c\/td\u003e\n\u003ctd\u003e10...60 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput voltage limits\u003c\/td\u003e\n\u003ctd\u003e10.2...72 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute maximum output\u003c\/td\u003e\n\u003ctd\u003e72 V constant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum voltage drop\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1 V at 2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum load current\u003c\/td\u003e\n\u003ctd\u003e12 A per module; 6 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge current\u003c\/td\u003e\n\u003ctd\u003e7.5 A for 50 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 1 ms, state 0 to state 1; \u0026lt;= 1 ms, state 1 to state 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum leakage current\u003c\/td\u003e\n\u003ctd\u003e1 mA at 60 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad inductance\u003c\/td\u003e\n\u003ctd\u003eInductance (H) = 0.5 \/ ((current (A))² x (switching frequency (Hz)))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection type\u003c\/td\u003e\n\u003ctd\u003eInternal output protection, 8 A fuse per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse used with relay\u003c\/td\u003e\n\u003ctd\u003e2 A per point; 8 A per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation between each channel and bus\u003c\/td\u003e\n\u003ctd\u003e2500 Vrms DC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation between groups\u003c\/td\u003e\n\u003ctd\u003e700 Vrms DC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddressing requirement\u003c\/td\u003e\n\u003ctd\u003e1 output word\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower consumption\u003c\/td\u003e\n\u003ctd\u003e1 W + (1 V x total module load current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus current requirement\u003c\/td\u003e\n\u003ctd\u003e160 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule class\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e1 green LED for communication on the bus (Active); 1 red LED for detected external fault (F); 16 green LEDs for output states\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic discharge immunity\u003c\/td\u003e\n\u003ctd\u003e4 kV on contact, 8 kV in air, according to IEC 801-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eImmunity to electromagnetic fields\u003c\/td\u003e\n\u003ctd\u003e10 V\/m, 80...2000 MHz, according to IEC 801-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e-40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95 % without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eCSA C22.2 No 142; UL 508\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eGOST; RMRS; FM Class I Division 2; C-Tick\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 type\u003c\/td\u003e\n\u003ctd\u003ePCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 quantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 length\u003c\/td\u003e\n\u003ctd\u003e30.91 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 width\u003c\/td\u003e\n\u003ctd\u003e16.33 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit 1 height\u003c\/td\u003e\n\u003ctd\u003e4.73 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking weight\u003c\/td\u003e\n\u003ctd\u003e452.6 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e18 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68313849692248,"sku":null,"price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/140DDO84300......jpg?v=1795500843","url":"https:\/\/gexufein.com\/products\/schneider-140ddo84300-modicon-quantum-discrete-output-module-16-outputs-10-60v-dc-positive-logic","provider":"Gexufein Automation","version":"1.0","type":"link"}