{"product_id":"schneider-140aci04000-analog-input-module-16ch-multirange-4-20ma","title":"Schneider 140ACI04000 Analog Input Module 16CH Multirange 4-20mA","description":"\u003ch2\u003e140ACI04000 - Analog Input Module, 16 Inputs, Multirange, Modicon Quantum\u003c\/h2\u003e\n\n\u003cp class=\"meta\"\u003eProduct type: \u003cstrong\u003eAnalog input module\u003c\/strong\u003e  |  Range: \u003cstrong\u003eModicon Quantum\u003c\/strong\u003e  |  Number of analog inputs: \u003cstrong\u003e16, differential\u003c\/strong\u003e  |  Ranges: \u003cstrong\u003e4...20 mA, 0...20 mA, 0...25 mA\u003c\/strong\u003e  |  Absolute accuracy: \u003cstrong\u003e±0.125 % of full scale\u003c\/strong\u003e  |  Update time: \u003cstrong\u003e15 ms\u003c\/strong\u003e  |  Address requirement: \u003cstrong\u003e17 input words\u003c\/strong\u003e  |  Bus current: \u003cstrong\u003e360 mA\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe 140ACI04000 is a 16-channel analog input module of the Modicon Quantum range. It is a current input module with three selectable ranges on the same reference: 4...20 mA, 0...20 mA and 0...25 mA, which is what the multirange designation on the front of the product refers to. The inputs are differential. Addressing requires 17 input words.\u003c\/p\u003e\n\n\u003cp\u003eResolution is quoted per range and per count format: 0...16000 counts on 4...20 mA, 0...20000 counts on 0...20 mA, 0...25000 counts on 0...25 mA, and 0...4095 counts on 4...20 mA. Wire-break detection is declared for the 4...20 mA range only, which is the practical reason to keep a live-zero range on a loop that has to be supervised. Input impedance is 250 ohm and the absolute maximum input is 30 mA. The wiring diagram carries one further limit that is easy to overlook: the maximum working voltage between channels must not exceed 30 Vdc.\u003c\/p\u003e\n\n\u003cp\u003eAbsolute accuracy error is ±0.125 % of full scale. Linearity error is a maximum of ±12 µA on 4...20 mA and a maximum of ±6 µA on 0...20 mA, 0...25 mA and the 0...4095-count 4...20 mA format. Temperature drift is ±0.0025 % of full scale per °C, with a second figure of 0.0050 % of full scale per °C or less. Common mode rejection is greater than −90 dB at 60 Hz. The input filter is a single-pole low-pass at −3 dB at 34 Hz ±25 %, and the update time is 15 ms for 2-wire and 4-wire connection.\u003c\/p\u003e\n\n\u003cp\u003eIsolation between each channel and the bus is 1780 V AC for 60 s. Bus current requirement is 360 mA and power dissipation is 5 W, both of which have to be carried in the backplane power budget rather than assumed. The module classification is standard.\u003c\/p\u003e\n\n\u003cp\u003eDiagnostics are on the front face: one green LED for bus communication activity, one red LED for an external fault, 16 green LEDs for channel on, and 16 red LEDs for channel fault, so a failed loop is identified at the channel rather than at the rack. The module carries the CE marking, is declared to UL 508 and CSA C22.2 No 142, and holds FM Class I Division 2 and cUL certification. Electrostatic discharge immunity is 4 kV on contact and 8 kV in air to IEC 801-2, and electromagnetic field immunity is 10 V\/m from 80 to 1000 MHz to IEC 801-3.\u003c\/p\u003e\n\n\u003cp\u003eOperating ambient air temperature is 0 to 60 °C, storage is −40 to 85 °C, relative humidity is 95 % without condensation, and operating altitude is up to 5000 m. Body dimensions are 290 mm high, 40.3 mm wide and 104 mm deep, or 144 mm deep with the field terminal block fitted. Net weight is 0.3 kg; one piece ships in a 310 x 165 x 46 mm carton of 433 g. The product is declared RoHS compliant, with a China RoHS declaration. Warranty is 18 months.\u003c\/p\u003e\n\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\n\u003ctable border=\"1\" cellpadding=\"7\" cellspacing=\"0\" style=\"border-collapse:collapse;width:100%;border-color:#d8dee6;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eCharacteristic\u003c\/th\u003e\n\u003cth align=\"left\" style=\"background:#0f5c8c;color:#ffffff;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange of product\u003c\/td\u003e\n\u003ctd\u003eModicon Quantum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct or component type\u003c\/td\u003e\n\u003ctd\u003eAnalog input module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of analog inputs\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput type\u003c\/td\u003e\n\u003ctd\u003eDifferential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ranges\u003c\/td\u003e\n\u003ctd\u003e4...20 mA; 0...20 mA; 0...25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog input resolution\u003c\/td\u003e\n\u003ctd\u003e0...16000 counts on 4...20 mA; 0...20000 counts on 0...20 mA; 0...25000 counts on 0...25 mA; 0...4095 counts on 4...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute maximum input\u003c\/td\u003e\n\u003ctd\u003e30 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum working voltage between channels\u003c\/td\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsolute accuracy error\u003c\/td\u003e\n\u003ctd\u003e±0.125 % of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity error\u003c\/td\u003e\n\u003ctd\u003e±12 µA max on 4...20 mA; ±6 µA max on 0...20 mA; ±6 µA max on 0...25 mA; ±6 µA max on 4...20 mA (0...4095 counts)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature drift accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.0025 % of full scale per °C; ≤ 0.0050 % of full scale per °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon mode rejection\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; −90 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole low-pass, −3 dB at 34 Hz ±25 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate time\u003c\/td\u003e\n\u003ctd\u003e15 ms, 2-wire and 4-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault type\u003c\/td\u003e\n\u003ctd\u003eWire break, 4...20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation between channel and bus\u003c\/td\u003e\n\u003ctd\u003e1780 V AC for 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAddress requirement\u003c\/td\u003e\n\u003ctd\u003e17 input words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus current requirement\u003c\/td\u003e\n\u003ctd\u003e360 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower dissipation\u003c\/td\u003e\n\u003ctd\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule classification\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal signalling\u003c\/td\u003e\n\u003ctd\u003e1 green LED bus communication activity; 1 red LED external fault; 16 green LEDs channel on; 16 red LEDs channel fault\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarking\u003c\/td\u003e\n\u003ctd\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eUL 508; CSA C22.2 No 142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct certifications\u003c\/td\u003e\n\u003ctd\u003eFM Class I Division 2; cUL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrostatic discharge immunity\u003c\/td\u003e\n\u003ctd\u003e4 kV contact, 8 kV air, per IEC 801-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromagnetic field immunity\u003c\/td\u003e\n\u003ctd\u003e10 V\/m, 80...1000 MHz, per IEC 801-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e290 x 40.3 x 104 mm (144 mm with field terminal block)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for operation\u003c\/td\u003e\n\u003ctd\u003e0...60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient air temperature for storage\u003c\/td\u003e\n\u003ctd\u003e−40...85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative humidity\u003c\/td\u003e\n\u003ctd\u003e95 % without condensation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating altitude\u003c\/td\u003e\n\u003ctd\u003e≤ 5000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRoHS\u003c\/td\u003e\n\u003ctd\u003eEU RoHS compliant; China RoHS declaration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet weight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit weight\u003c\/td\u003e\n\u003ctd\u003e433 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePacking unit dimensions\u003c\/td\u003e\n\u003ctd\u003e310 x 165 x 46 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWarranty\u003c\/td\u003e\n\u003ctd\u003e18 months\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n","brand":"Schneider Electric","offers":[{"title":"Default Title","offer_id":68277230534744,"sku":null,"price":558.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/140ACI04000......jpg?v=1795160831","url":"https:\/\/gexufein.com\/products\/schneider-140aci04000-analog-input-module-16ch-multirange-4-20ma","provider":"Gexufein Automation","version":"1.0","type":"link"}