{"product_id":"allen-bradley-5069-ib6f-3w-compact-5000-3-wire-dc-input-module","title":"Allen Bradley 1762-OX6I MicroLogix 1200 Output Module","description":"\u003cp\u003e\u003cspan\u003eThe 1762-OX6I output module is a MicroLogix 1200 series output module from Allen-Bradley. It is an isolated MicroLogix 1200 series relay output module. The 1762-OX6I isolated relay output module uses a flat ribbon cable with a female bus connector. This output module can be mounted on a DIN Rail or a panel and it should be mounted with at least 2 inches of space for airflow around it on all sides. The 1762-OX6I isolated relay output module can operate at 32 to 131 degrees Fahrenheit and it can be stored at -40 to 185 degrees Fahrenheit.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"w-full py-8\"\u003e\n\u003ch2 id=\"specifications\" class=\"text-black text-heading4\"\u003eTechnical specifications for 1762-OX6I\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-12\"\u003e\n\u003ctable class=\"w-full details mb-12\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eProduct Line\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eMicroLogix 1200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePart Number\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1762-OX6I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eUPC\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e781180001918\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e0.50 lbs (0.23 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eVoltage Category\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eAC\/DC Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eNo. of Inputs\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eSix (6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eNo. of Groups\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e6 groups; individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOutput Groups\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eOutputs 0 to 5: Individually isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOutput Form\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eType C Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOutput Voltage Range\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e5-125VDC and 120\/240VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCompatible Controllers\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eMicroLogix 1100, 1200 and 1400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePower Supply Distance rating\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSignal delay, On\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eSignal Delay, Off\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBus current draw, max\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e110 mA at 5V DC 110 mA at 24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOperating Voltage Range\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e5-264V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOutputs\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e(6) Isolated Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eMounting Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"description\" class=\"text-black text-heading4\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"text-gray-10 rotate-180\"\u003e\u003csvg color=\"currentColor\" class=\"size-28\" viewbox=\"0 0 24 24\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cpath d=\"M6 9L12 15L18 9\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"text-body1 text-gray-10 !leading-relaxed dynamic-content\"\u003e\n\u003cp\u003eThe Allen-Bradley 1762-OX6I is a MicroLogix 1200 I\/O expansion module. This module features Six (6) individually isolated Form C contact outputs. With Form C contact outputs, this module is designed with One (1) Normally Open and One (1) Normally Closed terminals therefore, it similarly functions as a switch however, each relay output states may be used to implement automation of different devices.\u003c\/p\u003e\n\u003cp\u003eEach relay output channels are designed to operate at voltage ranges of 5-125VDC and 5-265 VAC. It has a Bus current draw of 110 mA at 5V DC and 110 mA at 24V DC. Each channel exhibits a maximum signal delay 10 ms and typical delay of 6 ms for ON transition. For OFF transition, the maximum signal delay is 20 ms with typical delay of 12 ms. Each output channel has a continuous current per point of 7A.\u003c\/p\u003e\n\u003cp\u003eThe 1762-OX6I is compatible for use with MicroLogix 1100, MicroLogix 1200 and MicroLogix 1400 controllers. When used with MicroLogix 1100, Four (4) installation instances of 1762-OX6I is supported. Similarly, Six (6) for MicroLogix 1200 and Seven (7) for MicroLogix 1400 controllers.\u003c\/p\u003e\n\u003cp\u003eWhen installing this module, it requires a 2-inch clearance on all sides of the module. This clearance is similar to installation clearances of other modules. This clearance is specified to provide an adequate working space and promote adequate air-flow to prevent overheating.\u003c\/p\u003e\n\u003cp\u003eThe Allen-Bradley 1762-OX6I isolated relay output module operates with an input voltage range of 5 to 265 and 5-125VDC. This module has a bus current draw rang of 110 mA at 5 Volts DC (0.55 kW).\u003c\/p\u003e\n\u003cp\u003eBefore installing this module, the environment should be analyzed and studied since the mounting method will depend on the number of shocks or vibrations that the module could receive when operating. There are two ways to mount this module; usually, it can be mounted using a DIN rail with end anchors. The other way to mount this module that is recommended for environments with extreme vibrations is completed by using two Panhead screws per module. After having been mounted, the 1762-OX6I isolated relay output module can be connected to the controller and other I\/O equipment using a ribbon cable. The Allen-Bradley 1762-OX6I isolated relay output module has dimensions of 90 x 40 x 87 millimeters (3.54 x 1.58 x 3.43 inches) and it has an approximate shipping weight of 220 grams (0.485 pounds). This module can withstand an operating temperature of 0 to 55 degrees Celsius (-32 to 131 degrees Fahrenheit) and an altitude of 2000 meters (6561 feet).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43667380633688,"sku":null,"price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/1762-OX6I.jpg?v=1768584631","url":"https:\/\/gexufein.com\/products\/allen-bradley-5069-ib6f-3w-compact-5000-3-wire-dc-input-module","provider":"Gexufein Automation","version":"1.0","type":"link"}