{"product_id":"allen-bradley-1746-a13-slc500-chassis","title":"Allen Bradley 1746-P2 SLC Power Supply","description":"\u003cp\u003e\u003cspan\u003eThe Allen-Bradley 1746-P2 is a SLC 500 Power Supply. This Power Supply has a nominal Input Voltage of 120\/220 Volts AC. It has an internal Current capacity of 5 A at 5V dc 0.96 A at 24V dc. It provides a 24VDC voltage output with built-in fuse protection.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"w-full py-8\"\u003e\n\u003ch2 id=\"specifications\" class=\"text-black text-heading4\"\u003eTechnical specifications for 1746-P2\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"mt-12\"\u003e\n\u003ctable class=\"w-full details mb-12\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCategory\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003ePLCs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eProduct Line\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003ePart Number\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1746-P2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eGTIN\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e10662468088326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1.38 lbs (0.62 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eModule Type\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003ePower Supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInput Power\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e70 Watts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInput Voltage\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e120 to 220 Volts AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eTypical line power requirement\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e180VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInrush Current\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e20 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBackplane Current (5 Volts)\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eInternal Current Capacity\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e5 A at 5V dc; 0.96 A at 24V dc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOutput Voltage Range\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e18 to 30 Volts DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eCPU Hold up time\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e20 ms (full load) 3000 ms (no load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eBackplane Current (24 Volts)\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e0.46 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFrequency\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e47 to 63 Hertz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eLocation\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1746 Chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eUPC\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e10662468088326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eUNSPSC\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e32151706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e0 to 60 Celsius\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"border-y border-gray-70 first:border-t-0 last:border-b-0\"\u003e\n\u003cth class=\"text-left text-body1 text-bold py-10 pr-10 desktop:pr-[10rem] desktop:text-nowrap\"\u003eFuse Protection\u003c\/th\u003e\n\u003ctd class=\"text-left text-body1 py-10 desktop:w-[60%]\"\u003e1746-F1 or equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"description\" class=\"text-black text-heading4\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"text-gray-10 rotate-180\"\u003e\u003csvg color=\"currentColor\" class=\"size-28\" viewbox=\"0 0 24 24\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"\u003e\u003cpath d=\"M6 9L12 15L18 9\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\"\u003e\u003c\/path\u003e\u003c\/svg\u003e\u003c\/div\u003e\n\u003cdiv class=\"\"\u003e\n\u003cdiv class=\"text-body1 text-gray-10 leading-relaxed! dynamic-content\"\u003e\n\u003cp\u003eThe Allen-Bradley 1746-P2 is an SLC 500 modular power supply. It comes with an input voltage of 85-132 or 170-265V AC at 47-63 Hz. Its internal current capacity at 5V is 5 A and it is 0.96 A at 24V. This power supply also comes with a maximum user-supplied overcurrent protection of 15 A and a maximum inrush current of 20 A. It has a 180 VA typical line power requirement and an input terminal and backplane isolation of 1800V AC RMS for 1 s. User-power current capacity at 24V DC is 200 mA and the user-power voltage range of the power supply, also at 24V DC, is 18-30V DC.\u003c\/p\u003e\n\u003cp\u003eIt has a maximum of two AWG wires per terminal. Fuse protection is present with the 1746-P2 power supply but it is limited to guarding against fire hazards due to short-circuit conditions. It comes with an open-type enclosure and can only be installed in a 1746 chassis. The entire power supply measures 5.5 x 2.9 x 5.7 inches and weighs 1.1 kg or 2.5 lbs. Its operating temperature is from 0-60 Deg. Celsius. This power supply module has a jumper terminal that is used to set the input voltage to be applied to the device.\u003c\/p\u003e\n\u003cp\u003eWhen undervoltage operation happens, the 1746-P2 power supply will continue to power up the SLC 500 controllers for a short period. When the power supply continues to receive input voltage that is lower than the recommended operating range for a period of time longer than the CPU hold-up time, the controllers will turn off. It will only resume operations automatically when the power supply receives the recommended operating input voltage.\u003c\/p\u003e\n\u003cp\u003eFor overcurrent conditions, the 1746-P2 Series A and B will undergo a power supply shutdown and CPU fault. The recovery procedure is to reload the user program. For the 1746-P2 Series C, it will have a 24V DC user shutdown but the CPU continues its operation and the recovery procedure is to correct the overcurrent condition.\u003c\/p\u003e\n\u003cp\u003eThe 1746-P2 is a Power supply module primarily designed for use with the SLC 500 automation system platform. This power supply is installed in the leftmost of the SLC chassis.\u003c\/p\u003e\n\u003cp\u003eThe installation location of this power supply is not included in the slot count. The slot counting starts with Slot Zero (0) which is reserved for the Programmable Logic Controller’s (PLC) processor or SLC 500 communication adapter.\u003c\/p\u003e\n\u003cp\u003eWhen the front cover of the power supply is opened, the power supply’s front panel is exposed. This power supply has Five (5) terminals, jumper pins and internal fuse. These terminals are designed to accommodate AC line connection and DC power connection. One terminal function as ground terminal. The internal fuse has an equivalent part number replacement of 1746-F2. The jumper pins are used to set the correct input voltage setting, whether 100\/120 VAC or 200 \/ 240 VAC.\u003c\/p\u003e\n\u003cp\u003eAvoid electrical arc when working with the power supply. Disconnecting or connecting a wire with active supply may produce an electric arc which may damage the electronic backplane. It is important to perform operation when the input power is inactive. The power supply module itself is sensitive to voltage surges that may occur when starting high-inductive electrical loads. To avoid damage to the power supply module, isolation transformer may be installed to prevent voltage surges from entering the power supply.\u003c\/p\u003e\n\u003cp\u003eThis power supply features a hold-up time of 20 ms (full load) 3000 ms (no load). This feature allows the PLC processor to continue functioning even when power supply input voltage falls below the nominal supply level.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Allen Bradley","offers":[{"title":"Default Title","offer_id":43689905127512,"sku":null,"price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/1746-P1_1000x1000_1ee82614-fd99-459a-8daf-3f54876a07bc.jpg?v=1769240985","url":"https:\/\/gexufein.com\/products\/allen-bradley-1746-a13-slc500-chassis","provider":"Gexufein Automation","version":"1.0","type":"link"}