{"title":"Honeywell","description":null,"products":[{"product_id":"fs20x-flame-detector","title":"FS20X Flame Detector","description":"\u003cp\u003e\u003cspan\u003eBased on the foundation of the highly successful and reliable SS4 Flame Detector, the FS20X Flame Detector represents a quantum leap in integrating Infrared and Ultraviolet sensing technologies. The FS20X is a Multi-Spectrum and UV\/Dual IR\/VIS Flame Detector with a proven UV solar-blind sensor. The FS20X exhibits faster false-alarm free response to fires over a wider temperature range and with a much longer detection range compared to conventional UV\/IR detectors.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eConventional and older technology UV\/IR detectors, using narrow band 4.3 micron IR sensors, will not respond to smoky fires or if the detector lens is contaminated with oil and other substances since both UV and 4.3 micron signals are attenuated, obscured or absorbed by thick smoke or detector lens contaminants. Also, these old technology UV\/IR detectors will not alarm to any fire if they are installed behind ordinary window glass.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eDual microprocessors provide a high level of fail-safe operation combined with fast and reliable performance. The Master Microprocessor performs high-speed digital sampling and signal processing calculations: while the slave microprocessor handles various sensor data, performs communications, self-diagnostics and provides interface versatility: and additional memory for storing Event Log and FirePic™ data.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eThe FS20X Flame Detector has a detection range in excess of 200 feet (very high sensitivity setting) for the detection of a one square-foot Heptane reference fire and has a cone of vision greater in volumetric coverage than most UV\/IR detectors. This means fewer detectors can be used as compared to other manufacturers’ detectors.\u003c\/span\u003e\u003cbr\u003e\u003cspan\u003eAdditional Features and Benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePatented* WideBand IR™ Infrared combined with Ultraviolet\u003c\/li\u003e\n\u003cli\u003eDetection range greater than 200 feet to 1 sq. ft. heptane fire\u003c\/li\u003e\n\u003cli\u003ePatented* Electronic Frequency Analysis\u003c\/li\u003e\n\u003cli\u003eVisible Sensor for optimum false alarm rejection\u003c\/li\u003e\n\u003cli\u003eSelectable detection sensitivities\u003c\/li\u003e\n\u003cli\u003eSolar blind 90° full 100% cone-of-vision\u003c\/li\u003e\n\u003cli\u003eDual Microprocessors for reliable performance\u003c\/li\u003e\n\u003cli\u003eReal-time clock for accurate time dating of events\u003c\/li\u003e\n\u003cli\u003eFirePic™ — Up to 6 pre-fire event data storage\u003c\/li\u003e\n\u003cli\u003eEvent log — Up to 200 events with date and time stamp\u003c\/li\u003e\n\u003cli\u003eBuilt-in RS-485 ModBus Communication\u003c\/li\u003e\n\u003cli\u003eBuilt-in non-isolated 4-20 mA analog output (sink or source)\u003c\/li\u003e\n\u003cli\u003eAlarm, Fault and Fire Verification relays.\u003c\/li\u003e\n\u003cli\u003eAutomatic Optical Path and Electronic Self-Test\u003c\/li\u003e\n\u003cli\u003eWidest operating temperature range\u003c\/li\u003e\n\u003cli\u003ePatented* Electronics Module for components protection with plug-in terminations for easy field installation\u003c\/li\u003e\n\u003cli\u003eTwo ¾” NPT OR 25mm conduit entries\u003c\/li\u003e\n\u003cli\u003eLow power consumption\u003c\/li\u003e\n\u003cli\u003eHigh RFI and EMI immunity\u003c\/li\u003e\n\u003cli\u003eFM approved\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eBenefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions\u003c\/li\u003e\n\u003cli\u003eArc welding immunity\u003c\/li\u003e\n\u003cli\u003eFalse alarm rejection for all environmental conditions\u003c\/li\u003e\n\u003cli\u003eMinimal maintenance for trouble-free operation\u003c\/li\u003e\n\u003cli\u003ePC software and Interface Module (FSIM) for fault diagnostics real-time graphs (RTGs), and downloading of FirePics™ and event log\u003c\/li\u003e\n\u003cli\u003eSuitable for a wide variety of applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eFeatures \u0026amp; Benefits:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDetects hydrocarbon and non-hydrocarbon fuel fires in all environmental conditions\u003c\/li\u003e\n\u003cli\u003eRange greater than 200 feet to 1 sq. ft. heptane fire\u003c\/li\u003e\n\u003cli\u003eArc welding immunity\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan\u003eQuick Specs:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eField of view: 90° full 100% core of vision, ± 45° from on axis\u003c\/li\u003e\n\u003cli\u003eOperating voltage: 24 VDC nominal (18-32 VDC) - regulated\u003c\/li\u003e\n\u003cli\u003eSensitivity: Very high, high, medium and low - switch selectable\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46191178973272,"sku":null,"price":3714.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/FS20X-211-21-12_4730f2f3-a43f-438e-8a44-38f0ac18d6f9.jpg?v=1789958203"},{"product_id":"honeywell-rm7800l1087-flame-safeguard-burner-controller-7800-series-relay-module-with-valve-proving-120-vac-ul-csa-fm-iri-modulating","title":"Honeywell RM7800L1087 Flame Safeguard Burner Controller | 7800 Series Relay Module with Valve Proving | 120 Vac, UL\/CSA \u0026 FM\/IRI Modulating","description":"\u003ch3\u003eHoneywell RM7800L1087 — 7800 Series Relay Module with Valve Proving\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell RM7800L1087\u003c\/strong\u003e is a microprocessor-based integrated burner control (flame safeguard relay module) from the proven \u003cstrong\u003e7800 SERIES\u003c\/strong\u003e, designed for automatically fired gas, oil, or combination-fuel single-burner applications. It is engineered for \u003cstrong\u003eUL\/CSA Modulating and FM\/IRI Modulating\u003c\/strong\u003e burner systems and provides automatic burner sequencing, flame supervision, system status indication, self-diagnostics and troubleshooting in one compact, field-replaceable module.\u003c\/p\u003e\n\u003cp\u003eThis model includes the \u003cstrong\u003eValve Proving System (VPS)\u003c\/strong\u003e feature, which automatically proves the tightness of the main fuel shut-off valves before or after each burner cycle — helping you meet the highest industrial safety standards with confidence.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eYour Benefits at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eValve Proving System (VPS)\u003c\/strong\u003e — automatic leak test of main gas valves (MV1\/MV2) before, after, split or both cycles; also programmable to \"Never\"\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAutomatic burner sequencing\u003c\/strong\u003e — prepurge, ignition trials, main flame establishing, run, postpurge and safe shutdown\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlame supervision\u003c\/strong\u003e — compatible with Honeywell C7008A, C7009A, C7915A, C7012E\/F, C7061A\/F, C7076A\/D, C7961E\/F flame detectors and R7847 series amplifiers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKeyboard Display included\u003c\/strong\u003e — S7800A1142 (VFD) keypad\/display for setup and diagnostics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault annunciation\u003c\/strong\u003e — 127 fault codes with 6 historical faults for fast troubleshooting\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eField-proven safety\u003c\/strong\u003e — SIL 3 capability (per IEC 61508), built for commercial\/industrial applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBroad fuel compatibility\u003c\/strong\u003e — gas, oil, or combination fuel, single-burner applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eValve Proving System (VPS)\u003c\/strong\u003e The RM7800L1087 performs automatic seat-tightness tests of the two main fuel shut-off valves. Using the S7800A1142 keyboard display, you can schedule the test: \u003cstrong\u003eNever\u003c\/strong\u003e (as shipped), \u003cstrong\u003eBefore\u003c\/strong\u003e (with prepurge), \u003cstrong\u003eAfter\u003c\/strong\u003e (with postpurge), \u003cstrong\u003eBoth\u003c\/strong\u003e, or \u003cstrong\u003eSplit\u003c\/strong\u003e (MV2 high-pressure seat test before, MV1 low-pressure seat test after).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Sequence Control\u003c\/strong\u003e The module manages the full burner sequence: Standby → Prepurge → Pilot Flame Establishing Period (PFEP) → Main Flame Establishing Period (MFEP) → Run → Postpurge → Standby, with lockout and interlock monitoring throughout. Pilot flame establishing period is site-configurable (4 s or 10 s), and postpurge time is programmable up to 66 minutes (15 s default).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Diagnostics\u003c\/strong\u003e A VFD keyboard display (standard with the RM7800) enables complete system status, setup, and diagnostics without additional tools. Historical fault codes accelerate troubleshooting and reduce downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible System Integration\u003c\/strong\u003e The module mounts on a Q7800A\/B universal wiring subbase and works with plug-in flame amplifiers and purge timer cards. Optional accessories include a Personal Computer Interface, DATA CONTROLBUS MODULE™, remote display mounting, and Combustion System Manager™ software.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e表格\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Thermal Solutions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Family\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7800 SERIES Flame Safeguard Controls\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRM7800L1087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRelay Module with Valve Proving\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatically fired gas, oil, or combination-fuel single-burner; UL\/CSA Modulating and FM\/IRI Modulating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e120 Vac (+10 % \/ −15 %), 50 or 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 W maximum (Run mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Total Connected Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2000 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFusing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15 A max., Type SC or equivalent fast blow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eValve Proving\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eVPS test: Never \/ Before \/ After \/ Both \/ Split (programmable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePostpurge Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProgrammable up to 66 minutes (15 s as shipped)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePilot Flame Establishing Period\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 s or 10 s (jumper selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Flame Detectors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eC7008A, C7009A, C7915A, C7012E\/F, C7061A\/F, C7076A\/D, C7961E\/F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeyboard Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eS7800A1142 (VFD) included with RM7800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFault Codes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e127 codes, 6 historical faults\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSafety Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSIL 3 capability (per IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmbient Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−40…+60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax. Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85 % rh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWiring Base\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eQ7800A\/B universal wiring subbase (required, sold separately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUL, CSA, FM (per system configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eIndustrial and commercial gas\/oil fired boilers and burners\u003c\/li\u003e\n\u003cli\u003eProcess heaters, ovens and furnaces\u003c\/li\u003e\n\u003cli\u003eIncinerators and thermal oxidizers\u003c\/li\u003e\n\u003cli\u003eDual-fuel (gas\/oil) single-burner systems\u003c\/li\u003e\n\u003cli\u003eBurner management system upgrades and retrofits\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":46191477391448,"sku":null,"price":1714.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/RM7800L10875.jpg?v=1789962796"},{"product_id":"fs24x-9-fs24x-911-22-1-flame-detector","title":"FS24X-9 FS24X-911-22-1 Flame Detector","description":"\u003cp\u003eFS24X is a quantum leap in flame and fire detection with its sophisticated software and\u003cbr\u003edetection technology.\u003cbr\u003eThe FS24X is the latest generation high technology Multi-Spectrum Triple IR (IR\/IR\/IR\/Visible)\u003cbr\u003eFire and Flame Detector, which is part of our FSX family of advanced technology Electro-Optical\u003cbr\u003efire detectors. Using our patented WideBand IR™, WideBand 4.3 micron IR™, and Visible detection\u003cbr\u003etechnology, the FS24X is a quantum leap in flame and fire detection. Sophisticated software\u003cbr\u003ealgorithms and dual microprocessors ensure that the FS24X has the highest fire detection\u003cbr\u003eperformance combined with optimal false alarm rejection.\u003cbr\u003eThe WideBand IR™ Infrared technology using high-speed solid-state Quantum sensors allows\u003cbr\u003edetection of all types of fires, hydrocarbon and non-hydrocarbon, in all weather conditions. If the\u003cbr\u003edetector’s signal is blocked by ordinary window glass, the patented WideBand IR sensors will still\u003cbr\u003ealarm to the fire albeit at a reduced sensitivity and slower response time.\u003cbr\u003eThe FSX family of detectors feature our patented FirePic data storage and information retrieval\u003cbr\u003efacility. FirePic™ records pre-fire data, which can be recovered from the Detector’s non-volatile\u003cbr\u003eflash memory for post fire analysis and postulation of the fire cause. Additionally, unique Real-Time\u003cbr\u003eGraphing (RTG™) allows viewing of the data which the Detector actually sees. A combination of\u003cbr\u003eoutputs makes the FS24X a truly versatile detector for today’s demanding industrial requirements.\u003cbr\u003eThe FS24X detector has a detection range greater than 60 m (200 feet) (Very High Sensitivity\u003cbr\u003esetting) for the detection of a 0.1 m2 (one square-foot) Heptane reference fire and has a cone of\u003cbr\u003evision far greater in volumetric coverage than any other Multi-Spectrum IR Detector. This means\u003cbr\u003efewer Detectors can be used as compared to other manufacturers’ Detectors.\u003cbr\u003eDual microprocessors provide a high level of fail-safe operation\u003cbr\u003ecombined with fast and reliable performance. The master\u003cbr\u003emicroprocessor performs high-speed digital sampling and signalprocessing calculations, while the slave microprocessor handles\u003cbr\u003evarious sensor data, performs communications, self-diagnostics and\u003cbr\u003eprovides interface versatility and additional memory for storing Event\u003cbr\u003eLog and FirePic™ data.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48935707902040,"sku":null,"price":3428.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/FS24X-9FS24X-911-22-16.jpg?v=1789972514"},{"product_id":"honeywell-analytics-tl-2055-explosion-proof-ir-test-lamp-flame-simulator-for-fs18x-fs20x-fs24x-flame-detectors","title":"Honeywell Analytics TL-2055 Explosion-Proof IR Test Lamp \/ Flame Simulator | for FS18X FS20X FS24X Flame Detectors","description":"\u003ch3\u003eHoneywell Analytics TL-2055 — Explosion-Proof WideBand IR Test Lamp\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eHoneywell Analytics TL-2055\u003c\/strong\u003e is a portable, explosion-proof infrared test lamp (flame simulator) designed to functionally test Honeywell Fire Sentry flame detectors — \u003cstrong\u003eFS18X, FS24X (IR3) and FS20X (UV \/ IR \/ UV-IR)\u003c\/strong\u003e — externally in hazardous locations, without opening the detector or exposing the site to a real flame.\u003c\/p\u003e\n\u003cp\u003eBuilt into a rugged, copper-free aluminum housing with an explosion-proof design, the TL-2055 emits a wideband IR signal that simulates the spectral signature of a real fire, letting one person verify detector sensitivity, optical integrity, and alarm response in seconds. It is the field service professional's standard tool for planned maintenance and functional testing of Fire Sentry systems in classified areas.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eYour Benefits at a Glance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExplosion-proof \u0026amp; hazardous-location rated\u003c\/strong\u003e — Class I, Div. 1 \u0026amp; 2, Groups B, C, D; Class II, Div. 1 \u0026amp; 2, Groups E, F, G; Class III; NEMA 3, 4\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe functional testing\u003c\/strong\u003e — verifies Fire Sentry FS18X \/ FS24X \/ FS20X detectors in the field with no open flame\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePortable \u0026amp; self-contained\u003c\/strong\u003e — internal rechargeable 12 VDC battery pack; universal 110\/220 VAC wall charger included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRugged construction\u003c\/strong\u003e — copper-free aluminum (≤ 0.4 % Cu) with powder-coated finish, tamper-resistant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWideband IR output\u003c\/strong\u003e — simulates fire signature for accurate detector response testing\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplaceable service parts\u003c\/strong\u003e — gold-plated reflector lamp and NiMH battery pack are user-replaceable plug-in parts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWide temperature range\u003c\/strong\u003e — −30…+85 °C operating and storage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eFunctional Field Testing in Hazardous Areas\u003c\/strong\u003e The TL-2055 radiates a wideband infrared signal matching the detection band of Fire Sentry IR and IR3 detectors, and a UV signature for UV \/ UV-IR models. One operator can sweep the detector's field of view, confirm alarm response and sensitivity, and record the test — no ladders full of test gear, no hot work permits, no real flames.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExplosion-Proof Design\u003c\/strong\u003e The housing is machined from copper-free aluminum (less than 0.4 % copper) with a powder-coated finish, designed and certified for use in Class I, Div. 1 \u0026amp; 2, Groups B, C, D; Class II, Div. 1 \u0026amp; 2, Groups E, F, G; and Class III locations per NEMA 3 and 4. Suitable for offshore, petrochemical, oil \u0026amp; gas, and process plant environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRechargeable \u0026amp; Maintenance-Friendly\u003c\/strong\u003e Power is supplied by an internal 12 VDC nickel-metal hydride battery pack, recharged through the supplied AC\/DC wall converter (110\/220 VAC). The IR reflector lamp and battery are plug-in user-replaceable parts, keeping the tool in service with minimal downtime.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Field-of-View Control\u003c\/strong\u003e A cylindrical tube can be fitted over the front lid to reduce the tester's radiated field of view, allowing selective testing of individual detectors in dense arrays.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e表格\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHoneywell Analytics (Honeywell)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTL-2055 (HAZLOC version; safe-area version: TL-1055)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eExplosion-proof IR test lamp \/ flame simulator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFunctional testing of FS18X, FS24X (IR3), FS20X (UV \/ IR \/ UV-IR) flame detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInternal 12 VDC NiMH battery pack; rechargeable via AC\/DC wall converter (110\/220 VAC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHousing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCopper-free aluminum (\u0026lt; 0.4 % Cu), powder-coated, tamper-resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHazardous Location Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass I, Div. 1 \u0026amp; 2, Groups B, C, D; Class II, Div. 1 \u0026amp; 2, Groups E, F, G; Class III; NEMA 3, 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−30…+85 °C (−22…+185 °F), operating and storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (Ø × H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.81 in × 4.40 in (approx. 122 mm × 112 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 4 lb (approx. 1.8 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReplaceable Parts\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIR gold-plated reflector lamp; NiMH battery pack (user replaceable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccessories\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUniversal wall charger included; optional FOV-reduction tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePlanned \/ periodic functional testing of Fire Sentry flame detectors in hazardous areas\u003c\/li\u003e\n\u003cli\u003eOffshore platforms, oil \u0026amp; gas facilities, petrochemical and chemical plants\u003c\/li\u003e\n\u003cli\u003eRefineries, LNG terminals, power plants and process industries\u003c\/li\u003e\n\u003cli\u003eDetector maintenance, commissioning and troubleshooting\u003c\/li\u003e\n\u003cli\u003eSafety system inspection and audit programs\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":48936526807128,"sku":null,"price":5571.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0580\/2799\/9320\/files\/TL-205555.jpg?v=1789975204"}],"url":"https:\/\/gexufein.com\/collections\/honeywell.oembed","provider":"Gexufein Automation","version":"1.0","type":"link"}